manufactured but enjoy a maximum operating pressure of 25 MPa (3630 PSI) and a maximum
flow rate of 10 L/min (2.6 U.S.GPM), while contributing further to a space saving requirement.
Moreover, using wet armature solenoids, the valves ensure the long life.
Special Seals F: Special seals for phosphate ester type fluids (Omit if not required)
Up to 25 MPa (3630 PSI), 10 L/min (2.6 U.S.GPM)
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
These DSG-005 series solenoid operated directional valves are the pro- ducts newly developed
Due caution must be paid to maintaining control over contamination of the hydraulic fluids
which may otherwise lead t o breakdowns and shorten the life of the valve.
Sub-plate Mounting DIRECTIONAL VALVES DSG-005-∗∗∗-∗-30/3090
The maximum flow means the limited flow without inducing any abnormality to the operation
Always be sure to use hydraulic fluids within the stipulated conditions shown below:
2 Viscosity: 20-200 mm /s (100-930 SSU), Temperature: -15 to+60°C (5 to 140°F).
Recommended Viscosity and Oil Temperatures
Use 20 µm or finer line filter. Control of Contamination
compactly manufactured but enjoy a maximum operating pressure of 25 MPa (3630 PSI)
Model Number Designation DSG -005 -3 C 2 -D24 -30 ∗ Series Number Valve Size Number
40DSG: Solenoid Operated Directional Valve 005 3 2 C: Spring Centred B: Spring Offset 2,
3 AC A100, A200 DC D12, D24 30 Refer to
These DSG-005 series solenoid operated directional valves are the pro- ducts newly developed
as a "Mini-series". Compared with DSG-01 series, t he valves are much more compactly
For details, please refer to the "List of Standard Models and Maximum Flow" on pages 3 and 4.
Inrush current in the above table shows rms values at maximum stroke.
Design Standards: None.........Japanese Standard "JIS" and European Design Standard 90 . N. American Design Standard
Fluid Types Hydraulic Fluids Any type of hydraulic fluid listed in the table below can be used.
Mounting Bolts Four socket head cap screws in the table below are included.
Please maintain the degree of contamination within NAS 1638-Grade 1 1.
(changeover) of the valve. The maximum flow differs according to the spool type and operating conditions.
and a maximum flow rate of 10 L/min (2.6 U.S.GPM), while contributing further to a space saving requirement.
Moreover, using wet armature solenoids, the valves ensure the long life.
MPa (PSI) MPa (PSI) -1 min (Cycles/min)
of Valve Position Spool-Spring Arrangement Spool Type Coil Type Design Number Design Standard 2, 3
as a "Mini-series". Compared with DSG-01 series, t he valves are much more