the optimum viscosity range is 10-39 cSt [60-180 SUS], 

at normal operating temperatures. Viscosity should never fall below 6 cSt [45 SUS].

Axial piston motors share the design advantages of piston pumps to provide long-lasting power in a lightweight,

per milliliter greater than 15 µm.  When components with different cleanliness requirements are used in the same system,

the cleanest standard shoud be appllied. Fluid Recommendations (Refer to Eaton’s 

Hydraulic Fluid Recommendations Technical Data sheet #3-401) 

Dual Rotation     Various Porting Options     Fixed Displacements

Eaton Medium duty piston motors convert hydraulic energy supplied by the pump to mechanical energy. 

These motors are uniquely suited to fit any appliction 

that requires continuous rotary motion at a remote location from the power source.

Motor Piston Motor Piston Motors s s s s General Overview

Case Drain Installation Requirements CAUTION - Failure to meet these requirements may result in damage to the piston motor. 

• Install piston motors in such a position that the case drain assures an oil level at 

or above unit center line. • Oil level must be at or above the unit center line before starting the piston motor. •

 Provide a case drain line of adequate size to limit the case  pressure to specified maximum.

 Cleanliness In systems using Eaton medium duty piston motors, 

Compact     Lighweight Durable      Housing     Numerous Shaft Options  

Medium Duty Medium Duty Medium Duty Medium Duty Medium Duty Piston Motor Piston Motor Piston 

Maximum Displacement 12,3 cm3/r [.75 in3/r] 20,3 cm3/r [1.24 in3/r] Maximum Rated 

Speed 4500 RPM 3600 RPM Continuous Rated Pressure † 210 bar [3000 lbf/in2] 210 bar [3000 lbf/in2]

Output Torque at Rated Speed and Pressure 29 N  m [260 lbf  in] 62 N  m [550 lbf  in] Continuous Allowable Case Pressure

 1,7 bar [25 lbf/in2] 1,7 bar [25 lbf/in2] Continuous Inlet Temperature 107oC [225o F] 107o C 

[225o F] Weight/Single Motor (approximate) 4,9 kg [11 lbs] 4,9 kg [11 lbs]

 For a complete list of options, refer to the Model Code section of a given motor displacement.

the fluid must be maintained at ISO Cleanliness Code 18/ 13 or better per SAE J1165.

This code allows a maximum of 2,500 particles per milliliter greater than 5 µm and a maximum of 80 particles 

SAE Mounting Flanges     SAE O-Ring Porting    

 easily serviceable package. The chart below provides an overview of features. 

 In hydraulic systems using Eaton’s medium duty piston pumps and motors,  

 Maximum Rated Pressure †† 345 bar [5000 lbf/in2] 345 bar [5000 lbf/in2] Maximum Intermittent Pressure 

††† 370 bar [5400 lbf/in2] 370 bar [5400 lbf/in2] Input Flow at Rated Speed and Pressure 64 l/min [16.9 GPM]

 79 l/min [20.8 GPM] Output Power at Rated Speed and Pressure 13,8 kW [18.5 hp] 23,2 kW [31.1 hp] 